Table of Contents Table of Contents
Previous Page  1650 / 2894 Next Page
Information
Show Menu
Previous Page 1650 / 2894 Next Page
Page Background

1650

Anestesia por subespecialidades en el adulto

IV

69. Marymount J, Murphy GS: TEE Intraoperative

monitoring with transesophageal echocardiogra-

phy: Indications, risks, and training. Anesthesiol

Clin 24:737, 2006.

70. ASA/SCA taskforce on TEE. Practice guidelines for

perioperative TEE. Anesthesiology 84:986, 1996.

71. Miller D, Farah MG, Liner A, et al: The relation

between quantitative right ventricular ejection frac-

tion and indices of tricuspid annular motion and

myocardial performance. J Am Soc Echocardiogr

17:443, 2007.

72. Jaffe RA, Pinto FS, Schmittger I: Aspects of mecha-

nical ventilation affecting intra-atrial shunt flow

during general anesthesia. Anesth Analg 75:484,

1992.

73. Campos JH: Progress in lung separation. Thorac

Surg Clin 15:71, 2005.

74. Eberle B, Weiler N, Vogel N, et al: Computed tomo-

graphy based tracheobronchial image reconstruc-

tion allows selection of the individually appropriate

double-lumen tube size. J Cardiothorac Vasc Anesth

13:532, 1999.

75. Seymour AH: The relationship between the diame-

ters of the adult cricoid ring and main tracheobron-

chial tree: A cadaver study to investigate the basis

for double-lumen tube selection. J Cardiothorac

Vasc Anesth 17:299, 2003.

76. Bahk JH, Oh YS: Prediction of double-lumen tra-

cheal tube depth. J Cardiothorac Vasc Anesth

16:370, 1999.

77. Yasumoto M, Higa K, Nitahara K, et al: Optimal

depth of insertion of left-sided double-lumen endo-

bronchial tubes cannot be predicted from body

height in below average-sized adult patients. Eur J

Anaesthesiol 23:42, 2006.

78. Boucek CD, Landreneau R, Freeman JA, et al: A

comparison of techniques for placement of double-

lumen endobronchial tubes. J Clin Anesth 10:557,

1998.

79. Brodsky JB, Lemmens JMH: Left double-lumen

tubes: clinical experience with 1,170 patients. J Car-

diothorac Vasc Anesth 17:289, 2003.

80. Campos JH, Gomez MN: Pro: right-sided double-

lumen endotracheal tubes should be used routinely

in thoracic surgery. J Cardiothorac Vasc Anesth

16:246, 2002.

81. Fortier G, Coté D, Bergeron C, et al: New landmarks

improve the positioning of the left Broncho-Cath

double-lumen tube: Comparison with the classic

technique. Can J Anesth 48:790, 2001.

82. Inoue S, Nishimine N, Kitaguchi K, et al: Double-

lumen tube location predicts tube malposition and

hypoxemia during one-lung ventilation. Br J

Anaesth 92:195, 2004.

83. Yüceyar L, Kaynak K, Canturk E, et al: Bronchial

rupture with a left-sided polyvinylchloride double-

lumen tube. Acta Anaesthesiol Scand 47:622, 2003.

84. Weng W, DeCrosta DJ, Zhang H: Tension pneumo-

thorax during one-lung ventilation: A case report.

J Clin Anesth 14:529, 2002.

85. Peragallo RA, Swenson JD: Congenital tracheal

bronchus: The inability to isolate the right lung with

a Univent bronchial blocker tube. Anesth Analg

91:300, 2000.

86. Soto RG, Oleszak SP: Resection of the Arndt bron-

chial blocker during stapler resection of the left

lower lobe. J Cardiothorac Vasc Anesth 20:131–132,

2006.

87. Sandberg WS: Endobronchial blocker dislodgment

leading to pulseless electrical activity. Anesth Analg

100:1728, 2005.

88. Prabhu MR, Smith JH: Use of the Arndt wire-guided

endobronchial blocker. Anesthesiology 97:1325,

2002.

89. Hagihira S, Takashina M, Mori T, et al: One-lung

ventilation in patients with difficult airways. J Car-

diothorac Vasc Anesth 12:186, 1998.

90. JonesPM,HarleCC,

TurkstraTP:TheGlideScope

(R)

Cobalt videolaryngoscope—a novel single-use

device. Can J Anaesth 54:677, 2007.

91. Tobias JD: Variations on one-lung ventilation. J Clin

Anesth 13:35, 2001.

92. Saito T, Naruke T, Carney E, et al: New double intra-

bronchial tube (Naruke tube) for tracheostomized

patients. Anesthesiology 89:1038, 1998.

93. Larsson A, Malmkvist G, Warner O: Variations in

lung volume and compliance during pulmonary

surgery. Br J Anesth 59:585, 1987.

94. Lumb AB (ed): Nunn’s Applied Respiratory

Physiology, 6th ed. Philadelphia, Elsevier,

2005, p 25.

95. Bachrendtz S, Klingstadt C: Differential ventilation

and selective PEEP during anaesthesia in the lateral

decubitus posture. Acta Anaesth Scand 28:252,

1984.

96. Klingstedt C, Hedenstierna G, Lundqvist A, et al:

The influence of body position and differential ven-

tilation on lung dimensions and atelectasis forma-

tion in anaesthetized man. Acta Anaesthesiol Scand

34:315, 1990.

97. Mure M, Domino K, Robertson HT: Pulmonary

blood flow does not redistribute in dogs with repo-

sition from supine to left lateral position. Anesthe-

siology 89:483, 1998.

98. Klingstedt C, Hedenstierna G, Baehrendtz S, et al:

Ventilation-perfusion relationships and atelectasis

formation in the supine and lateral positions during

conventional mechanical mechanical and differen-

tial ventilation. Acta Anaesthesiol Scand 34:421,

1990.

99. Joyce CJ, Baker AB, Parkinson R, Zacharias M:

Nitrous oxide and the rate of gas uptake from an

unventilated lung in dogs. Br J Anaesth 76:292,

1996.

100. Schulte-Sasse U, Hess W, Tarnow J: Pulmonary vas-

cular responses to nitrous oxide in patients with

normal and high pulmonary vascular resistance.

Anesthesiology 57:9, 1982.

101. Bindslev L, Cannon D, Sykes MK: Reversal of

nitrous oxide induced depression of hypoxic

pulmonary vasoconstriction by lidocaine hydro-

chloride during collapse and ventilation hypoxia

of the left lower lobe. Br J Anaesth 58:451,

1986.

102. Rooke GA, Choi JH, Bishop MS: The effect of iso-

flurane, halothane, sevoflurane and triopental/

nitrous oxide on respirator resistance after tracheal

intubation. Anesthesiology 86:1294, 1997.

103. Al-Abdullatief M, Wahood A, Al-Shirawi N, et al:

Awake anesthesia for major thoracic surgical proce-

dures. Eur J Cardiothorac Surg 32:346, 2007.

104. Williams A, Kay J: Thoracic epidural anesthesia for

thoracoscopy, rib resection, and thoracotomy in a

patient with a bronchopleural fistula postpneumo-

nectomy. Anesthesiology 92:1482, 2000.

105. Ko R, Kruger M, McRae K, et al: Impact of inspired

gas mixtures on oxygenation and surgical condi-

tions during one lung ventilation. Can J Anesth

50:A13, 2003.

106. Tusman G, Bohm SH, Sipman FS, Maisch S: Lung

recruitment improves the efficiency of ventilation

and gas exchange during one-lung ventilation anes-

thesia. Anesth Analg 98:1604, 2004.

107. Szegedi LL, Van der Linden P, Ducart A, et al: The

effects of acute isovolemic hemodilution on oxyge-

nation during one-lung ventilation. Anesth Analg

100:15, 2005.

108. Hurford WE, Alfille PH: A quality improvement

study of placement and complications of double-

lumen endobronchial tubes. J Cardiothorac Vasc

Anesth 7:517, 1993.

109. Brodsky J, Lemmens HJ: Left double-lumen tubes:

Clinical experience with 1,170 patients. J Cardiotho-

rac Vasc Anesth 17:289, 2003.

110. Lumb AB (ed): Nunn’s Applied Respiratory Physio-

logy, 6th ed. Philadelphia, Elsevier, 2005, p 97.

111. Watanabe S, Noguchi E, Yamada S, et al: Sequential

changes in arterial oxygen tension in the supine

position during one-lung ventilation. Anesth Analg

90:28, 2000.

112. Bardoczky GI, Szegedi LL, d’Hollander AA, et al:

Two-lung and one-lung ventilation in patients with

chronic lung disease: The effects of position and

Fio

2

. Anesth Analg 90:35, 2000.

113. Moudgil R, Michelakis D, Archer SL: Hypoxic pul-

monary vasoconstriction. J Appl Physiol 98:390,

2005.

114. Dorrington KL, Clar C, Young JD, et al: Time course

of the human vascular response to 8 hours of iso-

capnic hypoxia. Am J Physiol Heart Circ Physiol

273:H1126, 1997.

115. Ishikawa S, Nakazawa K, Makita K: Progressive

changes in arterial oxygenation during one-lung

anesthesia are related to the response to compres-

sion of the non-dependent lung. Br J Anaesth 90:21,

2003.

116. Brimioulle S, Vachiery J-L, Brichant J-F, et al: Sym-

pathetic modulation of hypoxic pulmonary vaso-

constriction in intact dogs. Cardiovasc Res 34:384,

1997.

117. Wang JY, Russel GN, Page RD, et al: A comparison

of the effects of sevoflurane and isoflurane on arte-

rial oxygenation during one-lung anesthesia. Br J

Anesth 81:850, 2000.

118. Wang JY, Russel GN, Page RD, et al: A comparison

of the effects of desflurane and isoflurane on arterial

oxygenation during one-lung anesthesia. Anaesthe-

sia 55:167, 2000.

119. Benumof J: Isoflurane anesthesia and arterial oxy-

genation during one-lung ventilation. Anesthesio-

logy 64:419, 1986.

120. Reid CW, Slinger PD, Lewis S: Comparison of the

effects of propofol-alfentanil versus isoflurane anes-

thesia on arterial oxygenation during one-lung

anesthesia. J Cardiothroac Vasc Anesth 10:860,

1997.

121. Slinger P, Scott WAC: Arterial oxygenation during

one-lung anesthesia: A comparison of enflurane and

isoflurane. Anesthesiology 82:940, 1995.

122. Russell WJ, James MF: The effects on arterial hae-

moglobin oxygen saturation and on shunt of increa-

sing cardiac output with dopamine or dobutamine

during one-lung ventilation. Anaesth Intens Care

32:644, 2004.

123. Loepply JA, Scotto P, Riedel CE, et al: Effects of

acid/base status on acute pulmonary vasoconstric-

tion and gas exchange. J Appl Physiol 72:1787,

1993.

124. Larsson A, Malmkvist G, Werner O: Variations in

lung volume and compliance during pulmonary

surgery. Br J Anaesth 59:585, 1987.

125. Bardoczky GI, Yernault JC, Engleman E, et al: Intrin-

sic positive end-expiratory pressure during one-

lung ventilation for thoracic surgery. Chest 110:180,

1996.

126. Szegedi LL, Bardocky GI, Engleman EE, d’Hollander

AA: Airway pressure changes during one-lung ven-

tilation. Anesth Analg 84:1034, 1997.

127. van der Weff YD, van der Houwen HK, Heijamans

PJM, et al: Post-pneumonectomy pulmonary edema:

A retrospective analysis of incidence and possible

risk factors. Chest 111:1278, 1997.

128. Unzueta MC, Casas JI, Moral MV: Pressure-contro-

lled versus volume-controlled ventilation during

one-lung ventilation for thoracic surgery. Anesth

Analg 104:1029–1033, 2007.

129. Tugrul M, Camci E, Karadeni H, et al: Comparison

of volume controlled with pressure controlled ven-

tilation during one-lung anesthesia. Br J Anesth

79:306, 1997.

130. Slinger P: Pro: Low tidal volume is indicated for

one-lung ventilation. Anesth Analg 103:268–270,

2006.

131. Slinger P, Suissa S, Triolet W: Predicting arterial oxy-

genation during one-lung anaesthesia. Can J

Anaesth 39:1030, 1992.

132. Hurford WE, Kokar AC, Strauss HW: The use of

ventilation/perfusion lung scans to predict oxygena-

tion during one-lung anesthesia. Anesthesiology

64:841, 1987.

133. Ribas J, Jimenez MJ, Barbera JA, et al: Gas exchange

and pulmonary hemodynamics during lung resec-

tion in patients at increased risk. Chest 120:852,

2001.

134. Fujiwara M, Abe K, Mashimo T: The effect of

positive end-expiratory pressure and continuous