7. Watson MO, Sanderson P: Designing for attention
with sound: Challenges and extensions to ecologi-
cal interface design. Hum Factors 49:331-346,
2007.
8. Block FE: What is heart rate, anyway? J Clin Monit
10:366-370, 1994.
9. Mark JB: Monitoring heart rate.
In
Mark JB (ed):
Atlas of Cardiovascular Monitoring. New York,
Churchill Livingstone, 1998, pp 205-217.
10. Murray WB, Foster PA: The peripheral pulse wave:
Information overlooked. J Clin Monit 12:365-377,
1996.
11. Reisner A, Shaltis PA, McCombie D, Asada HH:
Utility of the photoplethysmogram in circulatory
monitoring. Anesthesiology 108:950-958, 2008.
12. Zong W, Moody GB, Mark RG: Reduction of false
arterial blood pressure alarms using signal quality
assessment and relationships between the electro-
cardiogram and arterial blood pressure. Med Biol
Eng Comput 42:698-706, 2004.
13. American Society of Anesthesiologists: Standards
for Basic Anesthetic Monitoring. 2005. Available at
http://www.asahq.org/publicationsAndServices/ standards/02.pdf/Accessed May 5, 2008.
14. Bruner JMR, Krenis LJ, Kunsman JM, Sherman AP:
Comparison of direct and indirect methods of mea-
suring arterial blood pressure. Med Instrum 15:11-
21, 1981, 97-101, 182-188.
15. Riva-Rocci S: Un nuovo sfigmomanometro. Gaz
Med Torino 47:981, 1896.
16. Korotkoff NS: On the subject of methods of deter-
mining blood pressure. Bull Imp Med Acad St
Petersburg 11:365, 1905.
17. Pickering TG, Hall JE, Appel LJ, et al: Recommen-
dations for blood pressure measurement in humans
and experimental animals: Part 1: Blood pressure
measurement in humans:A statement for professio-
nals from the Subcommittee of Professional and
Public Education of the American Heart Associa-
tion Council on High Blood Pressure Research.
Hypertension 45:142-161, 2005.
18. Cohn JN: Blood pressure measurement in shock.
Mechanism of inaccuracy in auscultatory and pal-
patory methods. JAMA 199:972-976, 1967.
19. Posey JA, Geddes LA, Williams H, Moore AG: The
meaning of the point of maximum oscillations in cuff
pressure in the indirect measurement of blood pressure.
Part 1. Cardiovasc Res Center Bull 8:15-25, 1969.
20. Yelderman M, Ream AK: Indirect measurement of
mean blood pressure in the anesthetized patient.
Anesthesiology 50:253-256, 1979.
21. Weiss BM,Pasch T: Measurement of systemic arterial
pressure. Curr Opin Anaesthesiol 10:459-466, 1997.
22. Alford JW, Palumbo MA, Barnum MJ: Com-
partment syndrome of the arm: A complication of
noninvasive blood pressure monitoring during
thrombolytic therapy for myocardial infarction.
J Clin Monit Comput 17:163-166, 2002.
23. Penaz J. In: Photoelectric measurement of blood pres-
sure, volume, and flow in the finger, 1973, p 104.
24. Bos WJW, van Goudoever J, van Montfrans GA,
et al: Reconstruction of brachial artery pressure
from noninvasive finger pressure measurements.
Circulation 94:1870-1875, 1996.
25. Belani K, ozaki M, Hynson J, et al: A new noninva-
sive method to measure blood pressure: Results of a
multicenter trial. Anesthesiology 91:686-692, 1999.
26. Cockings JGL, Webb RK, Klepper ID, et al: Blood
pressure monitoring—applications and limitations:
An analysis of 2000 incident reports.Anaesth Inten-
sive Care 21:565-569, 1993.
27. Eather KF, Peterson LH, Dripps RD: Studies of the
circulation of anesthetized patients by a new
method for recording arterial pressure and pressure
pulse contours. Anesthesiology 10:125-132, 1949.
28. Mark JB: Atlas of Cardiovascular Monitoring. New
York, Churchill Livingstone, 1998.
29. Mandel MA, Dauchot PJ: Radial artery cannulation
in 1000 patients. Precautions and complications. J
Hand Surg 2:482-485, 1977.
30. Slogoff S,Keats AS,Arlund C: On the safety of radial
artery cannulation. Anesthesiology 59:42-47, 1983.
31. Allen EV:Thromboangiitis obliterans: Methods of diag-
nosis of chronic obstructive lesions distal to the wrist
with illustrative cases.Am J Med Sci 178:237, 1929.
32. Wilkins RG: Radial artery cannulation and ischaemic
damage: A review. Anaesthesia 40:896-899, 1985.
33. Abu-Omar Y, Mussa S,Anastasiadis K, et al: Duplex
ultrasonography predicts safety of radial artery
harvest in the presence of an abnormal Allen test.
Ann Thorac Surg 77:116-119, 2004.
34. Barbeau GR, Arsenault F, Dugas L, et al: Evaluation
of the ulnopalmar arterial arches with pulse oxi-
metry and plethysmography: Comparison with the
Allen’s test in 1010 patients. Am Heart J 147:489-
493, 2004.
35. Tegtmeyer K, Brady G, Lai S, et al: Videos in clinical
medicine. Placement of an arterial line. N Engl J
Med 354:e13, 2006.
36. Chowet AL, Lopez JR, Brock-Utne JG, Jaffe RA:
Wrist hyperextension leads to median nerve con-
duction block: Implications for intra-arterial cathe-
ter placement. Anesthesiology 100:287-291, 2004.
37. Kuo MH, Leong CP, Chang YF, Chang HW: Static
wrist position associated with least median nerve
compression: Sonographic evaluation. Am J Phys
Med Rehabil 80:256-260, 2001.
38. Levin PD, Sheinin O, Gozal Y: Use of ultrasound
guidance in the insertion of radial artery catheters.
Crit Care Med 31:481-484, 2003.
39. Gerber DR, Zeifman WE, Khouli HI, et al: Compa-
rison of wire-guided and nonwire-guided radial
artery catheters. Chest 109:761-764, 1996.
40. Karacalar S, Ture H, Baris S, et al: Ulnar artery
versus radial artery approach for arterial cannula-
tion: A prospective, comparative study. J Clin
Anesth 19:209-213, 2007.
41. Bazaral MG, Welch M, Golding LAR, Badhwar K:
Comparison of brachial and radial arterial pressure
monitoring in patients undergoing coronary artery
bypass surgery. Anesthesiology 73:38-45, 1990.
42. Scheer B, Perel A, Pfeiffer UJ: Clinical review: Com-
plications and risk factors of peripheral arterial
catheters used for haemodynamic monitoring in
anaesthesia and intensive care medicine. Crit Care
6:199-204, 2002.
43. Muralidhar K: Complication of femoral artery
pressure monitoring. J Cardiothorac Vasc Anesth
12:128-129, 1998.
44. Rehfeldt KH, Sanders MS: Digital gangrene after
radial artery catheterization in a patient with
thrombocytosis. Anesth Analg 90:45-46, 2000.
45. Rose SH: Ischemic complications of radial artery
cannulation: An association with a calcinosis, Ray-
naud’s phenomenon, esophageal dysmotility, sclero-
dactyly, and telangiectasia variant of scleroderma.
Anesthesiology 78:587-589, 1993.
46. Singleton RJ,Webb RK, Ludbrook GL, Fox AL: Pro-
blems associated with vascular access: An analysis
of 2000 incident reports. Anaesth Intensive Care
21:664-669, 1993.
47. Gardner RM: Direct blood pressure measurement—
dynamic response requirements. Anesthesiology
54:227-236, 1981.
48. Kleinman B: Understanding natural frequency and
damping and how they relate to the measurement
of blood pressure. J Clin Monit 5:137-147, 1989.
49. Kleinman B, Powell S, Kumar P, Gardner RM: The
fast flush test measures the dynamic response of the
entire blood pressure monitoring system. Anesthe-
siology 77:1215-1222, 1992.
50. O’Quin R, Marini JJ: Pulmonary artery occlusion
pressure:Clinicalphysiology,measurement,and inter-
pretation. Am Rev Respir Dis 128:319-326, 1983.
51. Mark JB: Technical requirements for direct blood
pressure measurement.
In
Mark JB (ed): Atlas of
Cardiovascular Monitoring. New York, Churchill
Livingstone, 1998, pp 99-126.
52. Geddes LA: Handbook of Blood Pressure Measure-
ment. Clifton, NJ, Humana Press, 1991.
53. Schwid HA: Frequency response evaluation of
radial artery catheter-manometer systems: Sinusoi-
dal frequency analysis versus flush method. J Clin
Monit 4:181-185, 1988.
54. Sinha S, Jayaram R, Hargreaves CG: Fatal neuro-
glycopaenia after accidental use of a glucose 5%
solution in a peripheral arterial cannula flush
system. Anaesthesia 62:615-620, 2007.
55. Promonet C, Anglade D, Menaouar A, et al: Time-
dependent pressure distortion in a catheter-trans-
ducer system. Anesthesiology 92:208-218, 2000.
56. Gardner RM: Accuracy and reliability of disposable
pressure transducers coupled with modern pressure
monitors. Crit Care Med 24:879-882, 1996.
57. Skidmore K, Chen J, Litt L: Arterial catheter pres-
sure cable corrosion leading to artifactual diagnosis
of hypotension. Anesth Analg 95:1192-1195, 2002.
58. Courtois M,Fattal PG,Kovacs SJ,et al:Anatomically
and physiologically based reference level for mea-
surement of intracardiac pressures. Circulation
92:1994-2000, 1995.
59. Seo JH, Jung CW, Bahk JH: Uppermost blood levels
of the right and left atria in the supine position:
Implication for measuring central venous pressure
and pulmonary artery wedge pressure. Anesthesio-
logy 107:260-263, 2007.
60. O’Rourke MF, Gallagher DE: Pulse wave analysis. J
Hypertens 14:S147-S157, 1996.
61. Braunwald E,FishmanAP,CournandA: Time rela-
tionship of dynamic events in the cardiac cham-
bers, pulmonary artery and aorta in man. Circ Res
4:100-107, 1956.
62. Stouffer G: Arterial pressure.
In
Stouffer G (ed):
Cardiovascular Hemodynamics for the Clinician.
Malden, MA, Blackwell Futura, 2008, pp 57-66.
63. Franklin SS, Weber MA: Measuring hypertensive
cardiovascular risk: The vascular overload concept.
Am Heart J 128:793-803, 1994.
64. Frank SM, Norris EJ, Christopherson R, Beattie C:
Right- and left-arm blood pressure discrepancies in
vascular surgery patients. Anesthesiology 75:457-
463, 1991.
65. Kinzer JB, Lichtentrhal PR,Wade LD: Loss of radial
artery pressure trace during internal mammary
artery dissection for coronary artery bypass graft
surgery. Anesth Analg 64:1134-1136, 1985.
66. Mark JB: Arterial blood pressure. Direct vs. indirect
measurement. In Mark JB (ed): Atlas of Cardiovas-
cular Monitoring. New York, Churchill Livingstone,
1998, pp 81-89.
67. Dorman T, Breslow MJ, Lipsett PA, et al: Radial
artery pressure monitoring underestimates central
arterial pressure during vasopressor therapy in cri-
tically ill surgical patients. Crit Care Med 26:1646-
1649, 1998.
68. Urzua J, Sessler D, Meneses G, et al: Thermoregula-
tory vasoconstriction increases the difference
between femoral and radial arterial pressures. J Clin
Monit 10:229-236, 1994.
69. Chauhan S, Saxena N, Mehrotra S, et al: Femoral
artery pressures are more reliable than radial artery
pressures on initiation of cardiopulmonary bypass.
J Cardiothorac Vasc Anesth 14:274-276, 2000.
70. Hynson JM, Katz JA, Mangano DT: On the accuracy
of intra-arterial pressure m
easurement:Thepressure
gradient effect. Crit Care Med 26:1623-1624, 1998.
71. McGregor M: Pulsus paradoxus. N Engl J Med
301:480-482, 1979.
72. Shabetai R, Fowler NO, Guntheroth WG: The
hemodynamics of cardiac tamponade and constric-
tive pericarditis. Am J Cardiol 26:480-489, 1970.
73. Mark JB: Pericardial constriction and cardiac tam-
ponade.
In
Mark JB (ed): Atlas of Cardiovascular
Monitoring. New York, Churchill Livingstone, 1998,
pp 313-326.
74. Gelman S: Venous function and central venous
pressure: A physiologic story. Anesthesiology 108:
735-748, 2008.
75. Perel A: Assessing fluid responsiveness by the systo-
lic pressure variation in mechanically ventilated
patients. Anesthesiology 89:1309-1310, 1998.
76. Rooke GA: Systolic pressure variation as an indica-
tor of hypovolemia. Curr Opin Anaesthesiol 8:511-
515, 1995.
77. Marik PE: The systolic blood pressure variation as
an indicator of pulmonary capillary wedge pressure
1088
Control de la anestesia
III