Table of Contents Table of Contents
Previous Page  1205 / 2894 Next Page
Information
Show Menu
Previous Page 1205 / 2894 Next Page
Page Background

26. Lubbers DW, Opitz N: The pco

2

-/po

2

-optode: A

new probe for measurement of pco

2

or po

2

in fluids

and gases (authors’ transl). Z Naturforsch [C]

30:532–533, 1975.

27. Bland JM,Altman DG: Statistical methods for asses-

sing agreement between two methods of clinical

measurement. Lancet 1:307–310, 1986.

28. Ganter M, Zollinger A: Continuous intravascular

blood gas monitoring: Development, current tech-

niques, and clinical use of a commercial device. Br

J Anaesth 91:397–407, 2003.

29. Ganter MT: Accuracy and performance of a modi-

fied continuous intravascular blood gas monitoring

device during thoracoscopic surgery. J Cardiothorac

Vasc Anesth 18:587–591, 2004.

30. Weiss IK, Fink S, Harrison R, et al: Clinical use of

continuous arterial blood gas monitoring in the

pediatric intensive care unit. Pediatrics 103:440–

445, 1999.

31. Coule LW, Truemper EJ, Steinhart CM, Lutin WA:

Accuracy and utility of a continuous intra-arterial

blood gas monitoring system in pediatric patients.

Crit Care Med 29:420–426, 2001.

32. Hatherill M, Tibby SM, Durward A, et al: Conti-

nuous intra-arterial blood-gas monitoring in infants

and children with cyanotic heart disease. Br J

Anaesth 79:665–667, 1997.

33. Venkatesh B, Pigott DW, Fernandez A, Hendry SP:

Continuous measurement of arterial blood gas

status during total hip replacement: A prospective

study. Anaesth Intensive Care 24:334–341, 1996.

34. Larson CP Jr,Vender J,Seiver A: Multisite evaluation

of a continuous intraarterial blood gas monitoring

system. Anesthesiology 81:543–552, 1994.

35. Aschkenasy SV, Hofer CK, Zalunardo MP, et al: Pat-

terns of changes in arterial Po

2

during one-lung

ventilation: A comparison between patients with

severe pulmonary emphysema and patients with preserved lung function. J Cardiothorac Vasc Anesth

19:479–484, 2005.

36. Pavlidis T, Papaziogas B, Vretzakis G, et al: Conti-

nuous monitoring of arterial blood gases and pH

during laparoscopic cholecystectomy using a Para-

trend sensor. Minerva Chir 57:17–22, 2002.

37. Severinghaus JW: Takuo Aoyagi: Discovery of pulse

oximetry. Anesth Analg 105(6 Suppl): S1–S4, 2007.

38. Wouters PF, Gehring H, Meyfroid G, et al: Accuracy

of pulse oximeters: The European multi-center trial.

Anesth Analg 94:S13–S16, 2002.

39. Hannhart B, Haberer JP, Saunier C, Laxenaire MC:

Accuracy and precision of fourteen pulse oximeters.

Eur Respir J 4:115–122, 1991.

40. Tobin RM, Pologe JA, Batchelder PB: A characteri-

zation of motion affecting pulse oximetry in 350

patients. Anesth Analg 94:S54–S61, 2002.

41. Bebout DE, Mannheimer PD, Wun CC: Site-depen-

dent differences in the time t o detect changes in

saturation during low perfusion [abstract]. Crit

Care Med 29:A115, 2001.

42. Welch JP, DeCesare R, Hess D: Pulse oximetry: Ins-

trumentation and clinical application. Respir Care

35:584–601, 1990.

43. Salyer JW: Neonatal and pediatric pulse oximetry.

Respir Care 48:386–396, 2003.

44. Jay GD, Hughes L, Renzi FP: Pulse oximetry is accu-

rate in acute anemia from hemorrhage. Ann Emerg

Med 24:32–35, 1994.

45. Severinghaus JW, Koh SO: Effect of anemia on pulse

oximeter accuracy at low saturation. J Clin Monit

6:85–88, 1990.

46. Ralston AC, Webb RK, Runciman WB: Potential

errors in pulse oximetry. III: Effects of interferences,

dyes, dyshaemoglobins and other pigments. Anaes-

thesia 46:291–295, 1991.

47. Craft JA, Alessandrini E, Kenney LB, et al: Compa-

rison of oxygenation measurements in pediatric

patients during sickle cell crises. J Pediatr 124:93–

95, 1994.

48. Katoh R, Miyake T, Arai T: Unexpectedly low pulse

oximeter readings in a boy with unstable hemoglo-

bin Köln. Anesthesiology 80:472–474, 1994.

49. Next-generation pulse oximetry. Health Devices

3247-87, 2003.

50. Bohnhorst B, Poets CF: Major reduction in alarm

frequency with a new pulse oximeter. Intensive Care

Med 24:277–278, 1998.

51. Irita K, Kai Y,Akiyoshi K, et al: Performance evalua-

tion of a new pulse oximeter during mild hypother-

mic cardiopulmonary bypass. Anesth Analg 96:

11–14, 2003.

52. Durban CG, Rostow SK: Advantages of new techno-

logy pulse oximetry with adults in extremis. Anesth

Analg 94:S81–S83, 2002.

53. O’Malley GF: Non-invasive carbon monoxide mea-

surement is not accurate. Ann Emerg Med 48:477–

478, 2006.

54. Suner S, Partridge R, Sucov A, et al: Non-invasive

screening for carbon monoxide toxicity in the emer-

gency department is valuable. Ann Emerg Med

49:718–719, 2007, author reply 719.

55. Barker SJ, Curry J, Redford D, Morgan S: Measure-

ment of carboxyhemoglobin and methemoglobin

by pulse oximetry: A human volunteer study. Anes-

thesiology 107:892–897, 2007.

56. Dassel ACM, Graaff R, Sikkema M, et al: Reflectance

pulse oximetry at the forehead improves by pressure

on the probe. J Clin Monit 11:237–244, 1995.

57. East CE, Brennecke SP, King JF, et al: The effect of

intrapartum fetal pulse oximetry, in the presence of

a nonreassuring fetal heart rate pattern,on operative

delivery rates: A multicenter, randomized, contro-

lled trial (the FOREMOST trial). Am J Obstet

Gynecol 194:606.e1–606.e16, 2006.

58. Kyriacou PA, Powell SL, Jones DP, Langford RM:

Evaluation of oesophageal pulse oximetry in

patients undergoing cardiothoracic surgery. Anaes-

thesia 58:422–427, 2003.

59. Fournell A, Schwarte LA, Scheeren TW, et al:

Assessment of microvascular oxygen saturation in

gastric mucosa in volunteers breathing continuous

positive airway pressure. Crit Care Med 31:1705–

1710, 2003.

60. Nijland R, Jongsma HW, van den Berg PP, et al: The

effects of pulsating arteries on reflectance pulse oxi-

metry: Measurements in adults and neonates. J Clin

Monit 11:118–122, 1995.

61. Moller JT, Pederson T, Rasmussen LS: Randomized

evaluation of pulse oximetry in 20,802 patients: I.

Design, demography, pulse oximetry failure rate,

and overall complication rate. Anesthesiology

78:436–444, 1993.

62. Young D, Griffiths J: Clinical trials of monitoring in

anaesthesia, critical care and acute ward care: A

review. Br J Anaesth 97:39–45, 2006.

63. Ochroch EA, Russell MW, Hanson WC 3rd, et al:

The impact of continuous pulse oximetry monito-

ring on intensive care unit admissions from a post-

surgical care floor. Anesth Analg 102:868–875,

2006.

64. Moller JT, Johannessen NN, Espersen K, et al: Ran-

domized evaluation of pulse oximetry in 20,802

patients: II. Perioperative events and postopera-

tive complications. Anesthesiology 78:445–453,

1993.

65. Wheatley RG,ShepherdD,Jackson IJ,et al:Hypoxae-

mia and pain relief after upper abdominal surgery:

Comparison of i.m. and patient-controlled analge-

sia. Br J Anaesth 69:558–561, 1992.

66. Rosenberg J, Oturai P, Erichsen CJ, et al: Effect of

general anesthesia and major versus minor surgery

on late postoperative episodic and constant hypoxe-

mia. J Clin Anesth 6:212–216, 1994.

67. Gill NP, Wright B, Reilly CS: Relationship between

hypoxaemic and cardiac ischaemic events in the

perioperative period. Br J Anaesth 68:471–473,

1992.

68. Jubran A, Tobin MJ: Reliability of pulse oximetry in

titrating supplemental oxygen therapy in ventilator-

dependent patients. Chest 97:1420–1425, 1990.

69. Bierman MI, Stein KL, Snyder JV: Pulse oximetry in

the postoperative care of cardiac surgical patients:

A randomized controlled trial. Chest 102:1367–

1370, 1992.

70. Shamir M, Eidelman LA, Floman Y, et al: Pulse oxi-

metry plethysmographic waveform during changes

in blood volume. Br J Anaesth 82:178–181, 1999.

71. Monnet X, Lamia B, Teboul JL: Pulse oximeter as a

sensor of fluid responsiveness: Do we have our

finger on the best solution? Crit Care 9:429–430,

2005.

72. Michard F, Boussat S, Chemla D, et al: Relation

between respiratory changes in arterial pulse pres-

sure and fluid responsiveness in septic patients with

acute circulatory failure.Am J Respir Crit Care Med

162:134–138, 2000.

73. Cannesson M, Besnard C, Durand PG, et al: Rela-

tion between respiratory variations in pulse oxime-

try plethysmographic waveform amplitude and

arterial pulse pressure in ventilated patients. Crit

Care 9:R562–R568, 2005.

74. Cannesson M, Attof Y, Rosamel P, et al: Respiratory

variations in pulse oximetry plethysmographic

waveform amplitude to predict fluid responsiveness

in the operating room. Anesthesiology 106:1105–

1111, 2007.

75. Feissel M, Teboul JL, Merlani P, et al: Plethysmogra-

phic dynamic indices predict fluid responsiveness in

septic ventilated patients. Intensive Care Med

33:993–999, 2007.

76. Shelley KH, Jablonka DH, Awad AA, et al: What is

the best site for measuring the effect of ventilation

on the pulse oximeter waveform? Anesth Analg

103:372–377, 2006.

77. Mowafi HA: The efficacy of plethysmographic pulse

wave amplitude as an indicator for intravascular

injection of epinephrine-containing epidural test

dose in anesthetized adults.AnesthAnalg 101:1506–

1511, 2005.

78. Uemura A, Yagihara M, Miyabe M: Pulse oximeter

perfusion index as a predictor for the effect of pedia-

tric epidural block. Anesthesiology 105:A1354,

2006.

79. Hager H, Church S, Mandadi G, et al: The perfusion

index measured by a pulse oximeter indicates pain

stimuli in anesthetized volunteers. Anesthesiology

101:A514, 2004.

80. Beal AL, Cerra FB: Multiple organ failure syndrome

in the 1990s: Systemic inflammatory response and

organ dysfunction. JAMA 271:226–233, 1994.

81. for the Early Goal-Directed Therapy Collaborative

Group, Rivers E, Nguyen B, Havstad S, et al: Early

goal-directed therapy in the treatment of severe

sepsis and septic shock. N Engl J Med 345:1368–

1377, 2001.

82. Räsänen J, Downs JB, DeHaven B: Titration of con-

tinuous positive airway pressure by real-time dual

oximetry. Chest 92:853–856, 1987.

83. Connett RJ, Honig CR, Gayeski TE, Brooks GA:

Defining hypoxia: A systems view of Vo

2

, glycolysis,

energetics, and intracellular Po

2

. J Appl Physiol

68:833–842, 1990.

84. Dings J,Meixensberger J,Jager A,Roosen K: Clinical

experience with 118 brain tissue oxygen partial

pressure catheter probes. Neurosurgery 43:1082–

1095, 1998.

85. Hockel M,Knoop C,Schlenger K,et al: Intratumoral

po

2

predicts survival in advanced cancer of the

uterine cervix. Radiother Oncol 26:45–50, 1993.

86. McCormick PW, Stewart M, Goetting MG, et al:

Noninvasive cerebral optical spectroscopy for

monitoring cerebral oxygen delivery and hemody-

namics. Crit Care Med 19:89–97, 1991.

87. Kavanagh MC, Tsang V, Chow S, et al: A comparison

in individual murine tumors of techniques for mea-

suring oxygen levels. Int J Radiat Oncol Biol Phys

44:1137–1146, 1999.

88. Barnes PJ,Liew FY: Nitric oxide and asthmatic infla-

mmation. Immunol Today 16:128–130, 1995.

89. Gabriele C, Nieuwhof EM, Van Der Wiel EC, et al:

Exhaled nitric oxide differentiates airway diseases in

the first two years of life. Pediatr Res 60:461–465,

2006.

90. Dupont LJ,Demedts MG,Verleden GM: Prospective

evaluation of the validity of exhaled nitric oxide for

the diagnosis of asthma. Chest 123:751–756, 2003.

91. Purtz EP, Hess D, Kacmarek RM: Evaluation of elec-

trochemical nitric oxide and nitrogen dioxide

analyzers suitable for use during mechanical venti-

lation. J Clin Monit 13:25–34, 1997.

Monitorización respiratoria

1205

34

Sección III

Control de la anestesia

© ELSEVIER. Fotocopiar sin autorización es un delito